The OPS Series is RS-422 compatible. Encoder signals are “sending end terminated.” Therefore customer
receiving terminations are not required. If you elect to use them, the supply current will increase.
Optional RS-422 compliant circuitry for long cable runs in harsh electrical environments is illustrated below.
Appendix D
RS-422 Compliance