Mercury
1500V - Vacuum Rated
DDiiggiittaall OOuuttppuutt EEnnccooddeerr SSyysstteemm
IInnssttaallllaattiioonn MMaannuuaall
aanndd RReeffeerreennccee GGuuiiddee
Manual No. IM-M1500V Rev S7
Vacuum Wall
Customer
Controller
Preliminary 8/20/2008
Vue de la page 0
1 2 3 4 5 6 ... 18 19

Résumé du contenu

Page 1 - 1500V - Vacuum Rated

Mercury™1500V - Vacuum RatedDDiiggiittaall OOuuttppuutt EEnnccooddeerr SSyysstteemmIInnssttaallllaattiioonn MMaannuuaall aanndd RReeffeerreenncc

Page 2 - PPrreeccaauuttiioonnss

Installation InstructionsRotary Encoders - Using Alignment Tool - MountingAttach your hub/scaleassembly to the rotarydevice. Refer to theinterface dra

Page 3

Installation InstructionsRotary Encoders - Using Alignment Tool - AlignmentPage 95Proper sensor alignment may require minor adjustments to the sensor

Page 4 - 1500V Encoder System

Page 10Installation InstructionsRotary Encoders - Using Sin/Cos Signals - MountingAttach your hub/scaleassembly to the rotarydevice. Refer to theinter

Page 5 - Mercury 1500V Encoder System

5Page 114INDEX TRACK ALIGNMENTThe M1500V must be aligned for both the mainand index tracks. When properly aligned, thesensor will produce an index win

Page 6

Reference SectionInstallation of Linear Scales Page 12MicroE SystemsL0.2L0.6L0.2LBenching pinsPositioning the ScaleNote: Before beginning moun

Page 7

Page 13Installation Reference GuideMercury encoders require a minimum of 4.75V DC continuously. When designing circuits and extension cables to use M

Page 8

Page 14Mercury 1500VSignal Twisted PairA+ Pair 1A-B+ Pair 2B-Index+ Pair 3Index-+5V Pair 4GNDCustomer Interface Cable RequirementsCustomer ca

Page 9

Page 15SINE+/COSINE+Analog signal with nominal peak to peak amplitude of 0.8V. The output signal has a source impedance of 1KΩ. This signal is only

Page 10 - Installation Instructions

TroubleshootingProblemThe Power/Calibration indicator will not come on.Solution• Make sure the M1500V 15-pin D connector is fully seated and connected

Page 11

World Headquarters: 125 Middlesex Turnpike • Bedford • MA 01730 USAwww.microesys.com • [email protected] • T. [781] 266-5700 • F. [781] 266-

Page 12

IInnttrroodduuccttiioonnMicroE Systems was founded to advance encoder technology toa level never before achieved. Our objective was to design encoders

Page 13 - (nominal)

Page 1TTaabbllee ooff CCoonntteennttssSYSTEM ILLUSTRATION PAGEEncoder with Linear scale 2Encoder with Rotary scale 3INSTALLATION INSTRUCTIONSUsing S

Page 14 - Reference Section

15 pin standard D-sub connectorMercuryTM1500V Encoder System with Linear scaleEExxppaannddeedd VViieewwEnd locator pinMounting screws & flat wash

Page 15 - Installation Reference Guide

sensor Mercury 1500V Encoder System with Rotary scaleEExxppaannddeedd VViieewwTop reflective rotary scaleRotary glass scale Page 3Mounting screws &am

Page 16 - Shield Termination:

Installation InstructionsLinear Encoders - Using Alignment Tool - Mounting12Attach the scale to the base slide. Reference the preferreddatum on the in

Page 17

Installation InstructionsLinear Encoders - Using Alignment Tool - AlignmentProper sensor alignment may require minor adjustments to the sensor positio

Page 18 - Cleaning Scales

Page 623Be sure power is off beforeconnecting the sensor.Connect the M1500V to yourinterface electronics usingthe wire color/signalassigments describe

Page 19 - Contact MicroE Systems

Page 74INDEX TRACK ALIGNMENTThe M1500V must be aligned for both the main and index tracks.When properly aligned, the sensor will produce an index wind