Microe PurePrecision Manuel d'utilisateur Page 18

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 33
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 17
Page 18
Tape Scale, OPS Side Mount Configuration
Installation By Mounted Applicator Tool
NOTE:
After removing the blue protective film, the scale is ready for use and will
perform to specification.
The encoder will not function properly with the blue protective film installed.
It must be removed for proper encoder operation.
11.
Peel off the blue protective film.
Start the peeling process using a sharp tool, being careful not to damage the scale. Pull off the remaining
blue protective film. Clean the tape scale using alcohol or acetone and a lint-free cotton cloth.
NOTE:
Make sure you have on finger cots
or talc-free gloves.
NOTE:
If installing index/limits (Laser Tape II and PVGL glass), go to the “Stick-On
Index and Limit Marker Installation” section.
Vue de la page 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 32 33

Commentaires sur ces manuels

Pas de commentaire